Shortwave infrared imaging spent twenty years as a defence and research technology, priced accordingly. In the last two years it has crossed into industrial machine vision at scale: moisture inspection in food and pharmaceutical production, silicon wafer and solar cell inspection, plastic sorting, weld-through glass, and content inspection in packaging. InGaAs sensor prices have come down, illumination options have matured, and system integrators now quote SWIR lines at factory budgets.

For the optics supply chain, the change is a new volume demand at wavelengths that most catalogue products never considered.
Why SWIR changes the component list
Silicon sensors stop near 1100 nm; InGaAs sensors start where silicon ends. A SWIR camera sees 900–1700 nm, and everything in its optical path must be specified for that band. Three component categories carry the new load.
Shortpass filters for daylight rejection. Outdoor and high-ambient industrial scenes flood InGaAs sensors with sunlight, which is intense out to 1700 nm and beyond. A shortpass with a cut-off in the 1100–1400 nm range transmits the working band and rejects the solar background. Unlike visible shortpass filters, these sit in a wavelength region where coating material absorption behaviour differs and where the cut-off edge needs to be steep because the sensor keeps responding well past the cut point.
Sensor and chamber windows. Every SWIR camera has a window in front of the sensor, and the default borosilicate window absorbs meaningfully above 1500 nm in thick sections and fluoresces under some illumination. Volume SWIR programmes are re-specifying windows in fused silica or SWIR-optimised glass, with AR coatings centred in the 900–1700 nm band rather than the visible.
Illumination-side filtering. SWIR illumination — 1300, 1450, 1550 nm LED and laser sources — needs bandpass and cleanup filtering on the emitter and, in some architectures, hot-mirror-style elements to keep thermal load off the optics.
The specification details that get missed
Water absorption bands are the SWIR-specific trap. Atmospheric water vapour absorbs strongly around 1380–1450 nm, and the absorption is strong enough to matter inside a factory's air path. A system designed across that band without accounting for it will show inexplicable transmission dips. Either design around the band or control the path.
Cut-off edge temperature drift also behaves differently in this region, and many SWIR systems run warm — the camera enclosure sits near the illuminator and the process. A filter specified only at 23 °C will drift visibly in a 50 °C housing.
And the volumes change the supplier conversation. SWIR inspection lines order filters in thousands per programme, which makes lot-to-lot consistency and documented edge-position statistics a purchasing requirement rather than a nice-to-have.
What belongs on the SWIR filter drawing
- Passband and cut-off wavelength, stated at the working angle of incidence.
- Edge steepness and blocking depth over the full solar band that matters, with measurement method.
- Transmission floor across the passband, measured at production temperature.
- Water absorption band handling: avoid, or account for it.
- Substrate and window material, with SWIR fluorescence data.
- Operating temperature range and the expected drift within it.
SWIR machine vision is the rare case where a new sensor technology arrived, matured, and got cheap before the supporting optics catalogue caught up. For the next few years, the advantage goes to suppliers who build the 900–1700 nm product family deliberately rather than adapting visible parts one order at a time.